Understanding all the efficiency claims and how to compare various boilers will lead you to the correct purchase decision. Once you've made your selection, there are a few important aspects of your boiler that contribute to its overall efficiency, which require your ongoing attention. Here are 10 tips to help you better select, maintain, repair and optimize your boiler system:
1. A few points matter
The annual fuel bill for a boiler can easily be two to three times the installed cost of the unit. Boilers with just a few percentage points better efficiency can generally pay for themselves the first year in energy savings, and the savings are ongoing.
2. Size for actual use
In industrial uses, most boilers are oversized for the application and operate at less than optimal efficiency. Conventional fire-tube boilers maintain peak efficiency at 100 percent firing rate; they lose efficiency as the firing rate decreases. Steam generators maintain a flat efficiency curve with peak efficiency at any firing rate.
3. Maintain proper combustion
Excess air is required for combustion. Low excess air increases carbon monoxide (CO) and sooting. Too high excess air, however, uses energy and lowers efficiency. Seasonal changes in temperature and barometric pressure can cause excess air to fluctuate five to 10 percent.
Too much or too little fuel with the available combustion air can result in unburned fuel and carbon monoxide generation. A very specific amount of oxygen (O2) is needed for perfect combustion, and additional (excess) air is required for good combustion. Too much additional air can contribute to CO generation, lower efficiencies and, perhaps, unsafe conditions with heating equipment not lasting beyond its full service life. Carbon burned to carbon dioxide (CO2) will produce more heat per pound of fuel than when CO or smoke is produced.
4. Weigh linkage-less designs
Recently introduced linkage-less, combustion-control systems with servomotors controlling the air/fuel mixture ensure proper combustion based on standard environmental conditions. An additional oxygen sensor in the stack can help the system control the excess air based on changes in the environment.
5. Maintain water treatment
All boilers require proper water treatment to maintain peak efficiency and ensure long tube life. Soft water is required, so that the watersides of the tubes don't accumulate scale. Scale accumulation is one of the major causes of reduced efficiency. Just 0.125-inch of scale can reduce efficiency by three percent.
6. Monitor and manage TDS
Regular water treatment and monitoring also ensure that you're operating at the recommended level of total dissolved solids (TDS) for your type of boiler. Solids are controlled by blow-down, which essentially sends BTUs to the drain. Too little blow-down and the high TDS will cause foaming and carryover in conventional boilers. If your TDS is lower than recommended, you may be blowing down excessive water and wasting energy and chemicals.
7. Install stack economizers
All boilers exhaust gases hot enough to be productive and improve the overall efficiency of the steam system. Standard stack economizers can be used to preheat the boiler water, either before it enters the feed-water tank or before it enters the boiler. These types of economizers usually can improve the boiler's efficiency by three to four percent.
Condensing stack economizers take substantially more heat out of the exhaust stream than standard economizers and can heat water to approximately 104 degrees Fahrenheit (40 degrees Celsius). Efficiency gains of up to 15 percent are common. These systems are particularly attractive when there's a great demand for hot water in the process or elsewhere in the facility.
8. Bring back the condensate
Many older steam systems don't have condensate return pipes, or there are numerous leaks in the return system. Once the steam has done its work and condensed, there's still substantial energy contained in the liquid. To maximize process efficiency, this condensate should be returned to the feed-water tank and reused through the boiler. The energy in the condensate will greatly reduce the amount of steam required to preheat the feed-water, as well as reducing the amount of softening and chemical treatment that would be required for fresh makeup water.
9. Maintain and repair promptly
To ensure long system life, maintain the steam traps regularly and repair leaks promptly. When a steam trap fails, it allows steam to blow through along with the condensate. This loss of steam represents a substantial energy loss. Steam is a valuable commodity and the higher the pressure, the higher its value. It's important to repair steam leaks as soon as they occur. A leak not only wastes energy, but also boiler water and chemicals, and leaks can be dangerous to people and equipment. Steam that leaks through a 0.25-inch hole can waste up to US$2,000 per month in energy.
10. Insulate pipes and fittings
Though adequate insulation usually is part of new steam systems, older systems might not be sufficiently protected from heat losses. Any surface over 120 degrees Fahrenheit (49 degrees Celsius) should be insulated, including boiler surfaces and steam and condensate piping and fittings. Insulation frequently becomes damaged or removed during maintenance and isn't replaced. Steam leaks also can damage insulation. Insulation on a typical six-inch gate valve can save $300 per year. Installing and maintaining 90-percent efficient insulation on piping can save tens of thousands of dollar every year.
Significant opportunities exist for saving energy in your steam systems. Selecting the right boiler for your needs and designing/maintaining the overall steam system will result in lower overall operating costs.
Glenn Adgey is the general manager of Brampton, ON-based Clayton Sales & Service, Ltd. For more information, visit www.claytonindustries.com.
Last modified on Wednesday, 07 October 2009 15:58
1. A few points matter
The annual fuel bill for a boiler can easily be two to three times the installed cost of the unit. Boilers with just a few percentage points better efficiency can generally pay for themselves the first year in energy savings, and the savings are ongoing.
2. Size for actual use
In industrial uses, most boilers are oversized for the application and operate at less than optimal efficiency. Conventional fire-tube boilers maintain peak efficiency at 100 percent firing rate; they lose efficiency as the firing rate decreases. Steam generators maintain a flat efficiency curve with peak efficiency at any firing rate.
3. Maintain proper combustion
Excess air is required for combustion. Low excess air increases carbon monoxide (CO) and sooting. Too high excess air, however, uses energy and lowers efficiency. Seasonal changes in temperature and barometric pressure can cause excess air to fluctuate five to 10 percent.
Too much or too little fuel with the available combustion air can result in unburned fuel and carbon monoxide generation. A very specific amount of oxygen (O2) is needed for perfect combustion, and additional (excess) air is required for good combustion. Too much additional air can contribute to CO generation, lower efficiencies and, perhaps, unsafe conditions with heating equipment not lasting beyond its full service life. Carbon burned to carbon dioxide (CO2) will produce more heat per pound of fuel than when CO or smoke is produced.
4. Weigh linkage-less designs
Recently introduced linkage-less, combustion-control systems with servomotors controlling the air/fuel mixture ensure proper combustion based on standard environmental conditions. An additional oxygen sensor in the stack can help the system control the excess air based on changes in the environment.
5. Maintain water treatment
All boilers require proper water treatment to maintain peak efficiency and ensure long tube life. Soft water is required, so that the watersides of the tubes don't accumulate scale. Scale accumulation is one of the major causes of reduced efficiency. Just 0.125-inch of scale can reduce efficiency by three percent.
6. Monitor and manage TDS
Regular water treatment and monitoring also ensure that you're operating at the recommended level of total dissolved solids (TDS) for your type of boiler. Solids are controlled by blow-down, which essentially sends BTUs to the drain. Too little blow-down and the high TDS will cause foaming and carryover in conventional boilers. If your TDS is lower than recommended, you may be blowing down excessive water and wasting energy and chemicals.
7. Install stack economizers
All boilers exhaust gases hot enough to be productive and improve the overall efficiency of the steam system. Standard stack economizers can be used to preheat the boiler water, either before it enters the feed-water tank or before it enters the boiler. These types of economizers usually can improve the boiler's efficiency by three to four percent.
Condensing stack economizers take substantially more heat out of the exhaust stream than standard economizers and can heat water to approximately 104 degrees Fahrenheit (40 degrees Celsius). Efficiency gains of up to 15 percent are common. These systems are particularly attractive when there's a great demand for hot water in the process or elsewhere in the facility.
8. Bring back the condensate
Many older steam systems don't have condensate return pipes, or there are numerous leaks in the return system. Once the steam has done its work and condensed, there's still substantial energy contained in the liquid. To maximize process efficiency, this condensate should be returned to the feed-water tank and reused through the boiler. The energy in the condensate will greatly reduce the amount of steam required to preheat the feed-water, as well as reducing the amount of softening and chemical treatment that would be required for fresh makeup water.
9. Maintain and repair promptly
To ensure long system life, maintain the steam traps regularly and repair leaks promptly. When a steam trap fails, it allows steam to blow through along with the condensate. This loss of steam represents a substantial energy loss. Steam is a valuable commodity and the higher the pressure, the higher its value. It's important to repair steam leaks as soon as they occur. A leak not only wastes energy, but also boiler water and chemicals, and leaks can be dangerous to people and equipment. Steam that leaks through a 0.25-inch hole can waste up to US$2,000 per month in energy.
10. Insulate pipes and fittings
Though adequate insulation usually is part of new steam systems, older systems might not be sufficiently protected from heat losses. Any surface over 120 degrees Fahrenheit (49 degrees Celsius) should be insulated, including boiler surfaces and steam and condensate piping and fittings. Insulation frequently becomes damaged or removed during maintenance and isn't replaced. Steam leaks also can damage insulation. Insulation on a typical six-inch gate valve can save $300 per year. Installing and maintaining 90-percent efficient insulation on piping can save tens of thousands of dollar every year.
Significant opportunities exist for saving energy in your steam systems. Selecting the right boiler for your needs and designing/maintaining the overall steam system will result in lower overall operating costs.
Glenn Adgey is the general manager of Brampton, ON-based Clayton Sales & Service, Ltd. For more information, visit www.claytonindustries.com.